Register Address Register Name Function Read/Write Control
0x01
VERSION
Software ID Read only
Register Size Register structure
4 Bytes
Unsigned Int 16bits (HH-HL) Version Unsigned Int 16bits (LH-LL) Revision
Description:
Firmware identifier composed with a Version and Revision number.
Same Version with different Revision is backward compatible.
Example:
Firmware 0x0001000A = Version 1, Revision 10 is compatible with all earlier
revisions of the same version (ver 1.0 to 1.9). However, it has new
functionalities (which are deactivated by default) or code optimizations.